Cummins ISB4.5 CM2150 Fault Code: 3612 PID: SPN: 3361 FMI: 7 Aftertreatment Diesel Exhaust Fluid Dosing Unit – Mechanical System Not Responding or Out of Adjustment.
Circuit Description
The diesel exhaust fluid dosing unit performs many functions, one of which is to generate adequate diesel exhaust fluid pressure in the lines using a pump to allow for dosing. The diesel exhaust fluid controller provides a battery voltage supply and a ground to the diesel exhaust fluid dosing unit. The controller also supplies a signal to the dosing unit to control the diesel exhaust fluid output. This signal changes based on the diesel exhaust fluid pressure being commanded.
Component Location
The aftertreatment diesel exhaust fluid dosing unit location is OEM dependent. Refer to the OEM service manual for more information.
Conditions for Running the Diagnostics
This diagnostic runs at initial key ON.
Conditions for Setting the Fault Codes
The aftertreatment diesel exhaust fluid controller detects that an incomplete powerdown purge cycle has occurred.
Action Taken When the Fault Code is Active
The fault code will be set active immediately when the diagnostic runs and fails. This is a no-lamp fault.
Conditions for Clearing the Fault Code
-This fault code will go inactive upon successful completion of a powerdown and purge cycle of the SCR dosing system.
-This fault code can also be cleared with INSITE™ electronic service tool.
Shop Talk
The SCR system is programmed to automatically purge itself after the engine has shut down. Immediately following key OFF, the diesel exhuast fluid (DEF) return valve will be actuated and the dosing unit will pump any DEF left in the lines and dosing unit back to the DEF tank. The purge cycle can take up to 60 Seconds.
This is an information only fault code that indicates that something is not allowing the diesel exhaust fluid dosing unit to fully complete its purge cycle. Failure to complete the purge cycle could lead to deposits forming in the diesel exhaust fluid system or damage to the dosing unit caused by freezing of the diesel exhaust fluid. Make sure the battery power is not being removed from the SCR system immediately after engine shutdown via a main battery disconnect switch.
-
JOHN DEERE SERVICE ADVISOR 5.3.225 DATABASE AG + CF ENGLISH 2023
John Deere $250.00Rated 0 out of 5
-
Volvo Impact 2021 Trucks & Buses 06.2021 DVD 9116 Spare Parts Catalog
Trucks software $55.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 1.1.19.1 with keygen unlocked ( Hino trucks )
Hino $50.00Rated 0 out of 5 -
PACCAR Electronic Service Analyst 5.4.3.0 SW files 27.03.2021 software trucks
PACCAR $60.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0846 Transmission Pressure Switch Solenoid D Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2810 Solenoid G Electrical
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0875 Transmission Reverse Pressure Switch Circuit Malfunction
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0870 Transmission Pressure Switch Solenoid E Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5