Cummins ISB4.5 CM2150 Fault Code: 3596 PID: SPN: 4334 FMI: 2 Aftertreatment Diesel Exhaust Fluid Pressure Sensor – Data Erratic, Intermittent, or Incorrect.
Circuit Description
The diesel exhaust fluid controller provides a 5 volt supply and a ground to the diesel exhaust fluid pressure sensor. The pressure sensor provides a signal to the diesel exhaust fluid controller on the sensor signal circuit. This sensor signal voltage changes based on the diesel exhaust fluid pressure supplied by the dosing unit. The diesel exhaust fluid controller will detect a low signal voltage at low diesel exhaust fluid pressures, and a high signal voltage at high diesel exhaust fluid pressures. The aftertreatment diesel exhaust fluid pressure sensor reading is communicated to the ECM via the engine data link.
Component Location
The aftertreatment diesel exhaust fluid pressure sensor is internal to the aftertreatment diesel exhaust fluid dosing unit and can not be serviced separately.
Conditions for Running the Diagnostics
This diagnostic runs when diesel exhaust fluid dosing unit is fully primed, and is actively maintaining diesel exhaust fluid pressure in the dosing system.
Conditions for Setting the Fault Codes
The diesel exhaust fluid dosing unit is unable to maintain the commanded diesel exhaust fluid pressure.
Action Taken When the Fault Code is Active
-The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
Conditions for Clearing the Fault Code
-To validate the repair, the diesel exhaust fluid dosing system must be fully primed. This can be done by performing the Aftertreatment Diesel Exhaust Fluid Doser Pump Override test in INSITE™ electronic service tool.
-To validate the repair, start the engine and make sure the SCR dosing system is fully primed.
-The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
-The ECM will turn off the MIL after 3 consecutive ignition cycles that the diagnostic runs and passes.
-This fault code and MIL can also be cleared with INSITE™ electronic service tool.
Possible Causes
-Leaking diesel exhaust fluid lines
-Malfunctioning diesel exhaust fluid dosing unit
-
CLAAS WebTIC Offline [11.2021] Service Information – ENGLISH Language
CLAAS $100.00Rated 0 out of 5 -
Detroit Diesel Diagnostic Link DDDL 8.0 PRO PROFESSIONAL Software trucks
Detroit $25.00Rated 0 out of 5
-
Wabco ToolBox plus 13.7 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5 -
International Truck ISIS – Oncommand Service Information Q4.2020 [04.2020]
Navistar $85.00Rated 0 out of 5 -
JOHN DEERE SERVICE ADVISOR 5.3.225 DATABASE AG + CF ENGLISH 2023
John Deere $250.00Rated 0 out of 5 -
download Hitachi Construction Machinery MPDr Ver 3.7.0.0 [10.2020] Diagnostic Software
Hitachi $76.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0073 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0871 Transmission Pressure Switch Solenoid E Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
Allison Transmission – WTEC 2 MD/HD/B SERIES TRANSMISSIONS
Allison$20.00Original price was: $20.00.$16.00Current price is: $16.00.Rated 0 out of 5