Cummins ISB4.5 CM2150 Fault Code: 3568 PID: SPN: 5394 FMI: 7 Aftertreatment Diesel Exhaust Fluid (DEF) Dosing Valve – Mechanical System Not Responding or Out of adjustment.
Circuit Description
The aftertreatment DEF dosing valve is controlled by the aftertreatment DEF controller. When the engine ECM commands DEF dosing, the DEF controller sends a pulse width modulated (PWM) signal to the dosing valve, which opens the dosing valve and allows DEF to be sprayed into the exhaust stream.
Component Location
The aftertreatment DEF dosing valve is installed in the exhaust system. It is mounted directly to the aftertreatment decomposition tube, before the Selective Catalytic Reduction (SCR) catalyst. Installation position will vary, based on the aftertreatment architecture and the OEM.
Conditions for Running the Diagnostics
This diagnostic runs when the DEF dosing valve is being commanded on.
Conditions for Setting the Fault Codes
The DEF controller has detected a mechanical malfunction of the DEF dosing valve.
Action Taken When the Fault Code is Active
-The ECM illuminates the amber CHECK ENGINE lamp and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.
-An engine torque derate will be activated.
Conditions for Clearing the Fault Code
-This fault code can not be cleared with INSITE™ electronic service tool.
-To validate the repair, the DEF dosing valve must be commanded on in order for all diagnostics to run. This can be done by performing the Aftertreatment Diesel Exhaust Fluid (DEF) Doser Pump Override test in INSITE™ electronic service tool.
-The ECM will turn off the amber CHECK ENGINE lamp and/or MIL immediately after the diagnostic runs and passes.
-Use INSITE™ electronic service tool to verify the fault code is inactive.
-The inactive fault code will be cleared from the memory after 9600 hours of engine operation without a reccurrence.
Shop Talk
This fault detects a mechanical malfunction of the DEF dosing valve, or a pin-to-pin short in the DEF dosing valve circuit.
Contamination of the DEF can be a possible cause for this fault code.
-
Wabco ToolBox plus 13.7.0.1 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0875 Transmission Reverse Pressure Switch Circuit Malfunction
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2810 Solenoid G Electrical
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0100 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0846 Transmission Pressure Switch Solenoid D Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL INTERNATIONAL ENGINE VT275 (2005 & Newer)
INTERNATIONAL ENGINES $27.00Rated 0 out of 5