Cummins ISB4.5 CM2150 Fault Code: 2773 PID: SPN: 3226 FMI: 0 Aftertreatment Outlet NOx – Data Valid but Above Normal Operating Range – Most Severe Level.
Circuit Description
The aftertreatment outlet nitrogen oxides (NOx) sensor is a smart device and receives commands from the engine electronic control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor receives power and a ground directly from the battery. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary engine ECM using the J1939 data link. The aftertreatment outlet NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the outlet NOx emissions from the engine.
Component Location
The aftertreatment outlet NOx sensor location can vary, depending on engine application. It is usually located in the exhaust system at the outlet of the aftertreatment catalyst.
Conditions for Running the Diagnostics
This diagnostic has to meet specific engine and aftertreatment conditions to run and complete. The NOx sensor gathers data over varying engine speeds and loads. When enough data has been gathered, the diagnostic will run, make a pass/fail decision, and begin to gather data again.
Conditions for Setting the Fault Codes
This fault code is triggered when the diagnostic detects that the NOx output is higher than a calibratible value for two consecutive ignition cycles.
Action Taken When the Fault Code is Active
-The ECM illuminates the amber CHECK ENGINE light and/or the malfunction indicator lamp (MIL).
-An engine torque derate will be activated immediately when the fault code becomes active.
Conditions for Clearing the Fault Code
– This fault code cannot be cleared with INSITE™ electronic service tool. It is necessary to drive or operate the vehicle on a chassis dynamometer in order to validate the repair and for the fault code to go inactive.
-Connect to the engine with INSITE™ electronic service tool, and start the “Aftertreatment High NOx Reset Test” from the “ECM Diagnostic Tests” screen. Operate the vehicle per the instructions on the screen. If the completion status of the reset test slows or stops advancing, vary the engine speed and load until the reset test completes and a decision is made.
-The ECM will turn off the amber CHECK ENGINE light and/or MIL immediately after the diagnostic runs and passes.
-Use INSITE™ electronic service tool to verify that the fault code is inactive.
-The inactive fault code will be cleared from memory after the completion of 9600 hours of engine operation without a re-occurrence.
Possible Causes
-Diesel exhaust fluid quality is not within specification
-External leaks in diesel exhaust fluid dosing unit and/or diesel exhaust fluid lines
-Sulfur content of the diesel fuel is too high, fouling the SCR catalyst and resulting in high NOx
-Diesel exhaust fluid dosing valve has malfunctioned
-Aftertreatment diesel exhaust fluid dosing unit has malfunctioned or become damaged
-Diesel exhaust fluid dosing valve is partially or completely plugged.
-Aftertreatment SCR catalyst is damaged or missing
-
Volvo Intermediate Storage File Encryptor/Decryptor (Editor) VISFED 0.3.2
Trucks software $35.00Rated 0 out of 5 -
download MANCATS II v14.01 2014 Diagnostic software MAN CATS ( virtual machine )
MAN $75.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0848 Transmission Pressure Switch Solenoid D Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0870 Transmission Pressure Switch Solenoid E Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0875 Transmission Reverse Pressure Switch Circuit Malfunction
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL INTERNATIONAL ENGINE VT365 (2003 & Older)
INTERNATIONAL ENGINES $24.00Rated 0 out of 5 -
SERVICE MANUAL Carrie Starbird TDB/TDS-215 and Starbird PlusTDB/TDS-219
CARRIE $24.00Rated 0 out of 5 -
SERVICE MANUAL International Engines MaxxForce 5 (2007 & 2009)
INTERNATIONAL ENGINES $25.00Rated 0 out of 5