Cummins ISB4.5 CM2150 Fault Code: 2271 PID: 27 SPN: 27 FMI: 4 EGR Valve Position Circuit – Voltage Above Normal or Shorted to High Source.
Circuit Description
The engine control module (ECM) uses the EGR valve position sensor to determine whether or not the valve is meeting the commanded position. The ECM supplies 5 volts to the EGR valve position signal circuit, and the EGR valve position sensor outputs a voltage signal to the ECM, based on the valve position. The ECM converts this signal into a percentage value, 0 to 100, indicating valve position. A fully-opened valve is equivalent to 100 percent.
Component Location
The EGR valve position sensor is internal to the EGR valve assembly and can not be serviced separately.
Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is operating.
Conditions for Setting the Fault Codes
The ECM detects that the EGR valve position sensor signal voltage is greater than a calibratible value.
Action Taken When the Fault Code is Active
-The ECM illuminates the amber CHECK ENGINE light and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.
The EGR valve operation will be disabled and the EGR valve will be closed.
Conditions for Clearing the Fault Code
The ECM detects that the EGR valve position sensor signal voltage is greater than a calibratible value.
Action Taken When the Fault Code is Active
-The ECM illuminates the amber CHECK ENGINE light and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.
The EGR valve operation will be disabled and the EGR valve will be closed.
Conditions for Clearing the Fault Code
-To validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute. The EGR valve will perform an auto-zero immediately after key ON.
-The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
-The ECM will turn off the MIL after three consecutive ignition cycles that the diagnostic runs and passes.
-This fault code and MIL can also be cleared with the INSITE™ electronic service tool.
Possible Causes
-Open return in the harness, connectors, or sensor
-SIGNAL wire shorted to sensor supply
-Malfunctioning EGR valve position sensor
-Malfunctioning ECM.
NOTE: Do not supply 12-VDC to the EGR valve position sensor, or short the EGR valve motor wires to the EGR valve position sensor. The EGR valve position is rated at 5-VDC, and sensor damage can occur.
Related
-
John Deere & Hitachi Parts ADVISOR 2020 [08.2020] Offline DVD Spare Parts Catalog
John Deere $120.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0848 Transmission Pressure Switch Solenoid D Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2810 Solenoid G Electrical
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0846 Transmission Pressure Switch Solenoid D Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0875 Transmission Reverse Pressure Switch Circuit Malfunction
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1891 Engine Throttle Position Sensor Pulse Width Modulation (PWM) Signal Low Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL International Engines DT466 (2004-2006)
INTERNATIONAL ENGINES $45.00Rated 0 out of 5