Cummins ISB CM850 (2003-06) Fault Code: 341 PID: SID 253 SPN: 530 FMI: 2 Engine Control Module Data Lost – Data Erratic, Intermittent or Incorrect. Severe loss of data from the ECM.
Cummins ISB CM850 (2003-06) Fault Code: 341 PID: SID 253 SPN: 530 FMI: 2 Engine Control Module Data Lost – Data Erratic, Intermittent or Incorrect. Severe loss of data from the ECM.
Possible no noticeable performance effects, engine dying or hard starting. Fault information, trip information, and maintenance monitor data can be inaccurate.
Possible repairs:
1)Charge or replace the battery.
2)Tighten the loose connections and clean the terminals.
3)Repair or replace the OEM harness.
4)Replace the fuses.