Cummins ISB CM850 (2003-06) Fault Code: 2962 PID: 412 SPN: 412 FMI: 0 EGR Temperature – Data Valid But Above Normal Operating Range, Moderately Severe Level.
Cummins ISB CM850 (2003-06) Fault Code: 2962 PID: 412 SPN: 412 FMI: 0 EGR Temperature – Data Valid But Above Normal Operating Range, Moderately Severe Level.
Possible causes:
1)A fouled EGR cooler
2)High coolant temperature
3)Low coolant level
4)Malfunctioning EGR valve
5)Malfunctioning EGR valve position sensor
6)High exhaust temperatures
7)Improper coolant-and-water mix
8)Variable geometry turbocharger stuck closed.
Note: This fault code will probably not be active with no load on the engine in the shop. The engine must be loaded to trip this fault code and determine if the malfunction has been found and fixed.
Possible repairs:
1)Repair or replace the leaking component.
2)Drain and fill the cooling system with the proper mixture.
3)Replace the EGR valve.
4)Clean or replace the EGR cooler.
5)Replace the variable geometry turbocharger.
6)Replace the EGR differential pressure sensor.
-
download Hitachi Construction Machinery MPDr Ver 3.7.0.0 [10.2020] Diagnostic Software
Hitachi $76.00Rated 0 out of 5 -
DOWNLOAD NISSAN UD DIESEL PC-CONSULT DIAGNOSTIC 1.1.13 & PC-REPROMASTER 1.2.0
NISSAN UD $100.00Rated 0 out of 5
-
Wabco ToolBox plus 13.7.0.1 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5 -
CAT Engine Reprogramming Tool for flash programming C1.8, C2.4, C3.8 & C3.3B + Guide
CAT $50.00Rated 0 out of 5 -
Volvo Intermediate Storage File Encryptor/Decryptor (Editor) VISFED 0.3.2
Trucks software $35.00Rated 0 out of 5 -
Scania SDP3 2.48.6 Diagnosis & Programming for VCI 3 VCI3 without Dongle
Scania $30.00Rated 0 out of 5 -
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.30 Developer + Devtool + INSTALATION VIDEO!
Trucks software $60.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P0976 Shift Solenoid 2 (SS2) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2684 Actuator Supply Circuit Voltage 3 Open (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2686 Actuator Supply Circuit Voltage 3 High (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2724 Pressure Control Solenoid 1 (PCS1) – Stuck On
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1790 Gear Shift Module 1 Calibration Invalid
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0980 Shift Solenoid 3 (SS3) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097A Shift Solenoid 1 (SS1) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2669 Actuator Supply Voltage 2 Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0970 Pressure Control Solenoid 3 (PCS3) Control Circuit Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1891 Throttle Position Sensor (TPS) PWM Signal – Low Input
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0977 Shift Solenoid 2 (SS2) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0973 Shift Solenoid 1 (SS1) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5
-
SERVICE MANUAL International Engines DT466E & DT530E (1999 & Older)
INTERNATIONAL ENGINES $31.00Rated 0 out of 5 -
SERVICE MANUAL Eaton Gen III Automated TransmissionsTRSM0930 EN-USOctober 2020
TRUCK MANUALS $24.00Rated 0 out of 5