Cummins ISB CM850 (2003-06) Fault Code: 293 PID: 441 SPN: 441 FMI: 3 Auxiliary Temperature Sensor Input 1 – Voltage Above Normal, or Shorted to High Source. High signal voltage or open circuit detected at the OEM auxiliary temperature circuit.
Cummins ISB CM850 (2003-06) Fault Code: 293 PID: 441 SPN: 441 FMI: 3 Auxiliary Temperature Sensor Input 1 – Voltage Above Normal, or Shorted to High Source. High signal voltage or open circuit detected at the OEM auxiliary temperature circuit.
Possible causes:
1)Open return circuit in the harness, connectors, or sensor
2)Open signal circuit or shorted to a voltage source.
Possible repairs:
1)Replace the OEM temperature sensor.
2)Repair or replace the OEM harness.
3)Replace the ECM.
Related
-
CAT ET 2021A (Caterpillar Electronic Technician) + Factory Password (1 PC )
CAT $65.00Rated 0 out of 5 -
PACCAR Electronic Service Analyst 5.4.3.0 SW files 27.03.2021 software trucks
PACCAR $60.00Rated 0 out of 5 -
ddct Detroit diesel calibration tool (DDCT) v4.5 English Include Calibrations & Metafiles
Detroit $30.00Rated 0 out of 5 -
Volvo PROSIS Offline 2019 Parts Catalog Installation Service
Trucks software $45.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2686 Actuator Supply Circuit Voltage 3 High (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097A Shift Solenoid 1 (SS1) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2727 Pressure Control Solenoid 1 (PCS1) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1790 Gear Shift Module 1 Calibration Invalid
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2789 Clutch Adaptive Learning at Limit
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2641 Torque Management Feedback Signal – LRTP
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2669 Actuator Supply Voltage 2 Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2637 Torque Management Feedback Signal – SEM
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1892 Throttle Position Sensor (TPS) PWM Signal – High Input
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0979 Shift Solenoid 3 (SS3) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0973 Shift Solenoid 1 (SS1) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0976 Shift Solenoid 2 (SS2) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0122 Pedal Position Sensor Circuit – Low Voltage
1000 & 2000 Gen 5Rated 0 out of 5
-
SERVICE MANUAL Eaton Fuller® HD FR/FRO TransmissionsTRSM2400April 2013
TRUCK MANUALSRated 0 out of 5 -
SERVICE MANUAL International Engines DT466 & DT530 (1999-2000) B
INTERNATIONAL ENGINES $29.00Rated 0 out of 5