Cummins ISB CM850 (2003-06) Fault Code: 292 PID: 441 SPN: 441 FMI: 14 Auxiliary Temperature Sensor Input 1 – Special Instructions.
Cummins ISB CM850 (2003-06) Fault Code: 292 PID: 441 SPN: 441 FMI: 14 Auxiliary Temperature Sensor Input 1 – Special Instructions.
This fault code is activated when the temperature input from the OEM sensor exceeds the engine protection limit defined by the OEM. An engine power derate is possible depending on the OEM application.
Possible repairs:
1)The engine protection limit has been exceeded for the OEM supplied pressure or temperature input. Refer to the OEM troubleshooting manual.
-
PACCAR Electronic Service Analyst 5.4.3.0 SW files 27.03.2021 software trucks
PACCAR $60.00Rated 0 out of 5 -
Wabco ToolBox plus 13.7 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2724 Pressure Control Solenoid 1 (PCS1) – Stuck On
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2727 Pressure Control Solenoid 1 (PCS1) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2730 Pressure Control Solenoid 1 (PCS1) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0977 Shift Solenoid 2 (SS2) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2641 Torque Management Feedback Signal – LRTP
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0973 Shift Solenoid 1 (SS1) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2729 Pressure Control Solenoid 1 (PCS1) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2685 Actuator Supply Circuit Voltage 3 Low (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1790 Gear Shift Module 1 Calibration Invalid
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2637 Torque Management Feedback Signal – SEM
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097B Shift Solenoid 2 (SS2) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0122 Pedal Position Sensor Circuit – Low Voltage
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1891 Throttle Position Sensor (TPS) PWM Signal – Low Input
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0974 Shift Solenoid 1 (SS1) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2671 Actuator Supply Voltage 2 (HSD2) – High (Batt)
1000 & 2000 Gen 5Rated 0 out of 5
-
SERVICE MANUAL International Engines MaxxForce DT 9 10 (2007-2009)
INTERNATIONAL ENGINES $30.00Rated 0 out of 5