Cummins ISB CM850 (2003-06) Fault Code: 237 PID: SID 30 SPN: 644 FMI: 2 External Speed Command Input (Multiple Unit Synchronization) – Data Erratic, Intermittent, or Incorrect. The throttle input signal to the primary or secondary engine for multiple unit synchronization is less than 3 percent or more than 97 percent.
Cummins ISB CM850 (2003-06) Fault Code: 237 PID: SID 30 SPN: 644 FMI: 2 External Speed Command Input (Multiple Unit Synchronization) – Data Erratic, Intermittent, or Incorrect. The throttle input signal to the primary or secondary engine for multiple unit synchronization is less than 3 percent or more than 97 percent.
The J1939 datalink connections are part of the OEM harness. Location of the J1939 harness will vary by the OEM. Refer to the OEM manual for specific component location.
The configuration of the three pins inputs to the electronic control module (ECM) on the OEM harness determines if an engine is a primary or secondary engine. To activate a pin, the pin must be grounded. To deactivate a pin, the pin must be open circuit.
Possible repairs:
1)Repair or replace the OEM harness.
-
John Deere & Hitachi Parts ADVISOR 2020 [08.2020] Offline DVD Spare Parts Catalog
John Deere $120.00Rated 0 out of 5 -
JOHN DEERE SERVICE ADVISOR 5.3.225 DATABASE AG + CF ENGLISH 2023
John Deere $250.00Rated 0 out of 5 -
premium volvo tech tool update 2.8.150 diagnostic software 1pc
Trucks software $150.00Rated 0 out of 5
-
ddct Detroit diesel calibration tool (DDCT) v4.5 English Include Calibrations & Metafiles
Detroit $30.00Rated 0 out of 5 -
CAT ET 2021A (Caterpillar Electronic Technician) + Factory Password (1 PC )
CAT $65.00Rated 0 out of 5
Related products
-
SERVICE MANUAL International Engines DT466 & DT570 (2004-2006) D
INTERNATIONAL ENGINES $34.00Rated 0 out of 5