Cummins ISB CM850 (2003-06) Fault Code: 145 (Marine) PID: 110 SPN: 110 FMI: 4 Engine Coolant Temperature 1 Sensor Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at engine coolant temperature circuit.
Cummins ISB CM850 (2003-06) Fault Code: 145 (Marine) PID: 110 SPN: 110 FMI: 4 Engine Coolant Temperature 1 Sensor Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at engine coolant temperature circuit.
The engine coolant temperature sensor shares return wires in the engine harness with other sensors. A shorted return can cause multiple fault codes to be active. Before troubleshooting Fault Code 145, check for multiple fault codes.
Possible causes:
1)Signal shorted to ground in the harness.
2)Signal shorted to return or ground in the sensor.
Possible repairs:
1)Replace the engine coolant temperature sensor
2)Replace the ECM.
3)Replace the engine harness.
-
download Hitachi Construction Machinery MPDr Ver 3.7.0.0 [10.2020] Diagnostic Software
Hitachi $76.00Rated 0 out of 5 -
download MANCATS II v14.01 2014 Diagnostic software MAN CATS ( virtual machine )
MAN $75.00Rated 0 out of 5
-
Volvo Impact 2021 Trucks & Buses 06.2021 DVD 9116 Spare Parts Catalog
Trucks software $55.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.116 + APCI 2021 + devtool ( ONLINE )
Trucks software $80.00Rated 0 out of 5 -
CLAAS WebTIC Offline [11.2021] Service Information – ENGLISH Language
CLAAS $100.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.30 Developer + Devtool + INSTALATION VIDEO!
Trucks software $60.00Rated 0 out of 5
Related products
-
SERVICE MANUAL International Engines DT466 & DT530 (1995-1998)
INTERNATIONAL ENGINES $34.00Rated 0 out of 5