Cummins ISB CM850 (2003-06) Fault Code: 1117 (Marine) PID: SID 251 SPN: 627 FMI: 2 Power Lost without Ignition Off – Data Erratic, Intermittent, or Incorrect. Supply voltage to the ECM fell below +6.2-VDC momentarily, or the ECM was not allowed to power down correctly (retain battery voltage for 30 seconds after key OFF).
Cummins ISB CM850 (2003-06) Fault Code: 1117 (Marine) PID: SID 251 SPN: 627 FMI: 2 Power Lost without Ignition Off – Data Erratic, Intermittent, or Incorrect. Supply voltage to the ECM fell below +6.2-VDC momentarily, or the ECM was not allowed to power down correctly (retain battery voltage for 30 seconds after key OFF).
This fault is set active if the ECM battery supply voltage drops below +6.2-VDC while the keyswitch is in the ON position.
Make sure the ECM unswitched battery supply is coming directly from the battery and not the starter. If unswitched power is coming from the starter, it is possible for the battery voltage to drop low enough during cranking to set this fault active.
Where the fault code is inactive, familiarize yourself with the vehicle shutdown practices used by the operator. For example, if there are controls inside the cab that can interrupt the (ECM) power supply (before the end of the 30 second power down process after key OFF), these should be considered as a potential cause when the fault code is being addressed. This should be explained to the operator.
This fault can also be caused by resistance in the ECM battery supply (+) or (-) circuits. Resistance in these circuits can cause the voltage level at the ECM input to drop low enough to set Fault Code 1117 active.
This fault can also be caused by a short to ground in the injector wiring harness. Check to be sure the injector wires are oriented so that they will not interfere with a rocker lever or other components in the overhead system. Keep in mind that certain operating conditions could cause the rocker levers to operate outside their normal range of motion.
This fault code can also be caused by noise transmitted over the J1587 or J1939 data links. The transmitted noise can cause a momentary interruption in the ECM power, which causes Fault Code 1117 to log. During troubleshooting, isolate the engine from the vessel to determine if any of the data links are conducting noise to the engine.
Possible repairs:
1)Tighten the loose connections and clean the terminals.
2)Charge or replace the battery.
3)Replace the engine harness.
4)Replace the ECM.
5)Replace the OEM harness.
6)Replace the blown fuse(s).
Related
-
Volvo PROSIS Offline 2019 Parts Catalog Installation Service
Trucks software $45.00Rated 0 out of 5 -
Volvo Intermediate Storage File Encryptor/Decryptor (Editor) VISFED 0.3.2
Trucks software $35.00Rated 0 out of 5 -
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5 -
download Hitachi Construction Machinery MPDr Ver 3.7.0.0 [10.2020] Diagnostic Software
Hitachi $76.00Rated 0 out of 5
-
Eaton Service Ranger 4.9 Engineering 4.9 [05.2021] Engineering Level ( 1 PC )
Eaton $67.00Rated 0 out of 5 -
10 IN 1 FOR CAT SIS Caterpillar 2021 Full Service Dealer INCLUDING CAT 2019 C
CAT $110.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 v1.1.21.4 with keygen unlocked ( Hino trucks )
Hino $60.00Rated 0 out of 5 -
Volvo PROSIS Offline 2019 Parts Catalog Installation Service
Trucks software $45.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P1891 Throttle Position Sensor (TPS) PWM Signal – Low Input
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2789 Clutch Adaptive Learning at Limit
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2730 Pressure Control Solenoid 1 (PCS1) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2671 Actuator Supply Voltage 2 (HSD2) – High (Batt)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2641 Torque Management Feedback Signal – LRTP
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2727 Pressure Control Solenoid 1 (PCS1) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097B Shift Solenoid 2 (SS2) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0977 Shift Solenoid 2 (SS2) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097C Shift Solenoid 3 (SS3) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1892 Throttle Position Sensor (TPS) PWM Signal – High Input
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2684 Actuator Supply Circuit Voltage 3 Open (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0970 Pressure Control Solenoid 3 (PCS3) Control Circuit Low
1000 & 2000 Gen 5Rated 0 out of 5