CAT 3406E (Prefix 5DS or 1LW) Fault Code: 00 PID: 171 SPN: FMI: 3 Ambient Air Temperature voltage high
The ECM detects the following conditions:
•The signal voltage from the ambient air temperature sensor is greater than 4.92 VDC for more than eight seconds.
•The “Allow Idle Shutdown Override” parameter is programmed to “Outside Temperature Based” or “J1587 Outside Temperature Based”.
•The ECM has been powered for at least two seconds.
Probable Causes:
1) ECM Connection/Harness
2) If code 232-3 or 232-4 (5 Volt Supply voltage codes) are active, troubleshoot those instead
3) Temperature sensor failure
4) Temperature sensor harness
5) ECM Failure
-
DOWNLOAD Paccar ESA Electronic Service Analyst 5.5.0 Diagnostic Software 2023
PACCAR $96.00Rated 0 out of 5 -
10 IN 1 FOR CAT SIS Caterpillar 2021 Full Service Dealer INCLUDING CAT 2019 C
CAT $110.00Rated 0 out of 5
Related products
-
DPF EGR SCR BAC ERG Delete & Flash CAAT Cummings Detroit Dodge Mack Volvo Collection of DELETE files
CAT $200.00Rated 0 out of 5 -
10 IN 1 FOR CAT SIS Caterpillar 2021 Full Service Dealer INCLUDING CAT 2019 C
CAT $110.00Rated 0 out of 5 -
CAT 3126B Fault Code: 168-00 PID: Flash Code 51 SPN: 168 FMI: 0 Excessive ECM Battery Power
3126BRated 0 out of 5 -
CAT 3126B Fault Code: 168-01 PID: Flash Code 51 SPN: 168 FMI: 1 Low ECM Battery Power
3126BRated 0 out of 5 -
CAT 3126B Fault Code: 231-11 PID: Flash Code 58 SPN: 639 FMI: 12 J1939 Data Link Fault
3126BRated 0 out of 5
-
SERVICE MANUAL International Engines MaxxForce 7 (2007-2009)
INTERNATIONAL ENGINES $31.00Rated 0 out of 5 -
SERVICE MANUAL INTERNATIONAL ENGINE VT365 (2004 & Newer)
INTERNATIONAL ENGINES $24.00Rated 0 out of 5