CAT 3406E (Prefix 1MM or 2WS) Fault Code: 47 PID: SPN: 71 FMI: 14 PTO Shutdown
The ECM detects the following conditions:
•The timer for the PTO has expired and the engine has shut down.
Probable Causes:
1) ECM Connection/Harness
2) PTO timer programmed incorrectly
3) PTO timer operated correctly and shut down as it is programmed to do
4) Check engine light or PTO switch on lamp failure
5) Vehicle speed circuit/sensor
6) PTO switch circuit/sensor
Related
-
Scania SDP3 2.48.6 Diagnosis & Programming for VCI 3 VCI3 without Dongle
Scania $30.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 v1.1.21.4 with keygen unlocked ( Hino trucks )
Hino $60.00Rated 0 out of 5 -
International Truck ISIS – Oncommand Service Information Q4.2020 [04.2020]
Navistar $85.00Rated 0 out of 5
Related products
-
CAT 3126B Fault Code: 231-11 PID: Flash Code 58 SPN: 639 FMI: 12 J1939 Data Link Fault
3126BRated 0 out of 5 -
CAT 3126B Fault Code: 168-00 PID: Flash Code 51 SPN: 168 FMI: 0 Excessive ECM Battery Power
3126BRated 0 out of 5 -
CAT 3126B Fault Code: 168-01 PID: Flash Code 51 SPN: 168 FMI: 1 Low ECM Battery Power
3126BRated 0 out of 5 -
CAT 3126B Fault Code: 231-02 PID: Flash Code 58 SPN: 639 FMI: 2 J1939 Data Incorrect
3126BRated 0 out of 5 -
CAT 3126B Fault Code: 252-11 PID: Flash Code 59 SPN: 631 FMI: 11 Incorrect Engine Software
3126BRated 0 out of 5 -
CAT 3126B Fault Code: 111-01 PID: Flash Code 62 SPN: 111 FMI: 17 Low Coolant Level Warning
3126BRated 0 out of 5 -
CAT 3126B Fault Code: 70-05 PID: Flash Code 49 SPN: 729 FMI: 5 Inlet Air Heater Open Circuit
3126BRated 0 out of 5
-
SERVICE MANUAL International Engines MaxxForce 7 (2007-2009)
INTERNATIONAL ENGINES $31.00Rated 0 out of 5