Allison 3000 & 4000 Gen 4 Fault Code: P2814 Pressure Control Solenoid 6 (PCS6) Control Circuit Low
DIAGNOSTIC RESPONSE:
DNS, SOL OFF (hydraulic default)
CIRCUIT DESCRIPTION:
Pressure Control Solenoid 6 (PCS6) is a normally closed solenoid used to apply the C6 clutch in Low (L) range (7-speed models only). The Transmission Control Module (TCM) commands the solenoid ON to produce hydraulic pressure in the clutch apply circuit. When PCS6 is commanded OFF, the clutch pressure is released. The TCM sends control current to PCS6 from High Side Driver 1 (HSD1) via wire 111. HSD1 is continuously ON unless the TCM detects a fault condition. The TCM regulates the amount of current to PCS6 by switching PCS6 low side driver ON and OFF. Wire 178 completes the circuit between PCS6 and its low side driver. DTC P2814 indicates that the TCM has detected a failed low condition in the PCS6 electrical circuit. The condition may exist in the high side (wire 111) or low side (wire 178).
CONDITIONS FOR RUNNING THE DTC:
TCM initialized normally and engine speed above 200 rpm.
CONDITIONS FOR SETTING THE DTC:
This DTC sets when the TCM detects PCS6 low side driver has been detected in a failed low state.
ACTION TAKEN WHEN THE DTC SETS:
When DTC P2814 is active:
1. If failure occurs while in a forward range, then shift to another forward range. If failure occurs while in Neutral (N), the transmission remains in Neutral (N). If failure occurs while in Reverse (R), transmission remains in Reverse (R) or shifts to Neutral (N). Once range is attained, transmission will be locked in range. There is no response to shift selector requests.
2. DTC is stored in the TCM history.
3. The CHECK TRANS light illuminates.
4. The TCM freezes shift adapts (DNA).
CONDITIONS FOR CLEARING THE DTC:
Use the diagnostic tool to clear the DTC from the TCM history. The TCM automatically clears the DTC from the TCM history if the vehicle completes 40 warm-up cycles without failures.
DIAGNOSTIC AIDS:
DTC P2814 can be caused by:
1. PCS6 issues such as:
– W178 shorted to another wire or ground in chassis harness.
– W178 (terminal 7 of 20-way) shorted to another wire or ground in internal transmission harness.
– PCS6 defective.
2. Broken on defective connector assemblies allowing pushed back pins to short together.
3. Unlocked connectors, missing seal plugs allowing moisture in connectors.
4. Defective TCM.
Review applicable information in Control System and Transmission Specifications to find additional circuit specifications, system and connector diagrams, and troubleshooting tips.
Related
-
DOWNLOAD Paccar ESA Electronic Service Analyst 5.5.0 Diagnostic Software 2023
PACCAR $96.00Rated 0 out of 5
-
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00Rated 0 out of 5 -
CAT Engine Reprogramming Tool for flash programming C1.8, C2.4, C3.8 & C3.3B + Guide
CAT $50.00Rated 0 out of 5 -
ddct Detroit diesel calibration tool (DDCT) v4.5 English Include Calibrations & Metafiles
Detroit $30.00Rated 0 out of 5 -
10 IN 1 FOR CAT SIS Caterpillar 2021 Full Service Dealer INCLUDING CAT 2019 C
CAT $110.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P1891 Engine Throttle Position Sensor Pulse Width Modulation (PWM) Signal Low Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0846 Transmission Pressure Switch Solenoid D Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0871 Transmission Pressure Switch Solenoid E Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL International Engines DT466 & DT530 (1999-2000) B
INTERNATIONAL ENGINES $29.00Rated 0 out of 5