PACCAR MX (2004 Emissions) Fault Code: P0274 Common Rail Pump Unit 2 – Voltage Too High or Short Circuit to Supply on ECU (D420) Pin (A28)
PACCAR MX (2004 Emissions) Fault Code: P0274 Common Rail Pump Unit 2 – Voltage Too High or Short Circuit to Supply on ECU (D420) Pin (A28)
SET CONDITIONS:
This DTC is set when the ECU detects a higher voltage than expected on the signal or control circuit of the ECU.
DIAGNOSTIC CONDITION:
The diagnostic runs continuously when the ignition is keyed on.
CORRESPONDING OBD READINESS MONITOR:
None
RESET CONDITION:
The DTC changes to inactive after the diagnostic runs and passes.
REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.
3. Did the DTC come back?
– No, repair successful
– Yes, repair unsuccessful
POSSIBLE CAUSES:
1. The sensor or actuator signal wiring has a short circuit to supply.
2. A malfunction of the sensor or actuator
ADDITIONAL INFORMATION:
When this DTC is active:
1. The engine torque is reduced.
2. The engine runs in protection mode.
3. The maximum rail pressure is limited to 1300 bar.
-
volvo Devtool Studio V2 / V3 / V4 Developer tool plus 2.6 / 2.7
Trucks software $35.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.116 + APCI 2021 + devtool ( ONLINE )
Trucks software $80.00Rated 0 out of 5 -
DOWNLOAD Paccar ESA Electronic Service Analyst 5.5.0 Diagnostic Software 2023
PACCAR $96.00Rated 0 out of 5
Related products
-
SERVICE MANUAL DETROIT DIESEL DDEC III-IV Single ECM Troubleshooting Guide
DETROIT $48.00Rated 0 out of 5 -
SERVICE MANUAL International Engines VT275 (2004 & Older)
INTERNATIONAL ENGINES $21.00Rated 0 out of 5