Cummins ISL CM850 (2003-06) Fault Code: 238 PID: SID 232 SPN: 611 FMI: 4 Sensor Supply 3 Circuit – Voltage Below Normal, or Shorted to Low Source. Low voltage detected on the +5 volt sensor supply circuit to the engine speed sensor.
Cummins ISL CM850 (2003-06) Fault Code: 238 PID: SID 232 SPN: 611 FMI: 4 Sensor Supply 3 Circuit – Voltage Below Normal, or Shorted to Low Source. Low voltage detected on the +5 volt sensor supply circuit to the engine speed sensor.
Low voltage on the +5 VDC supply line can be caused by a short circuit to ground in a supply line, a short circuit between a supply line or a return line, a failed sensor, or a failed ECM power supply.
Possible repairs:
1)Replace the engine speed sensor.
-
Scania SDP3 2.48.6 Diagnosis & Programming for VCI 3 VCI3 without Dongle
Scania $30.00Rated 0 out of 5 -
premium volvo tech tool update 2.8.150 diagnostic software 1pc
Trucks software $150.00Rated 0 out of 5
-
John Deere & Hitachi Parts ADVISOR 2020 [08.2020] Offline DVD Spare Parts Catalog
John Deere $120.00Rated 0 out of 5 -
CAT Engine Reprogramming Tool for flash programming C1.8, C2.4, C3.8 & C3.3B + Guide
CAT $50.00Rated 0 out of 5 -
2021 VOLVO PREMIUM TECH TOOL PTT V2.8.21 VCADS+DEVELOPER TOOL+APCI 2021/09 ( 1 PC )
Trucks software $85.00Rated 0 out of 5 -
PF Diagnose 2.0.2.23 Diagnostics Software 2013 – Full Heavy & Medium Duty with OBDII Support – Online Installation Service
PF Diagnose $60.00Rated 0 out of 5 -
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5 -
Volvo Impact 2021 Trucks & Buses 06.2021 DVD 9116 Spare Parts Catalog
Trucks software $55.00Rated 0 out of 5
Related products
-
SERVICE MANUAL International Engines DT466 (2004-2006)
INTERNATIONAL ENGINES $45.00Rated 0 out of 5