Volvo Engine D12D AE E3 (Tier 3) Fault Code: SID230 FMI 3 Idle Validation Switch
Volvo Engine D12D AE E3 (Tier 3) Fault Code: SID230 FMI 3 Idle Validation Switch
DETECTION CONDITIONS:
The engine control unit (E-ECU) registers:
1. Accelerator pedal not applied.
2. That the voltage is above 0.75xUbat. (EB15)
SYMPTOM:
Limp home mode not functioning.
POSSIBLE CAUSES:
1. Short circuit to battery voltage between E-ECU and V-ECU.
2. Accelerator pedal defective.
-